Especificaciones
Conexion neumatica | Mounting Position | Operating Pressure | Peso |
---|---|---|---|
For tubing O.D. 6 mm For tubing O.D. 8 mm For tubing outside diameter of 10 mm For tubing O.D. 12 mm For tubing outside Ø 1/4" For tubing outside Ø 5/16" For tubing outside Ø 3/8" | optional | 0 MPa ... 1 MPa | 160g |
LABS (PWIS) conformity | VDMA24364-B1/B2-L | ||
Protection class | III | ||
Degree of protection | IP65 | ||
Setting options | IO-Link® Teach-in Via display and keys | ||
Display type | Illuminated LCD, multi-colour | ||
Product weight | 160 g | ||
Mounting position | optional | ||
Electrical connection 1, connection pattern | 00995383 | ||
Electrical connection 1, connector system | M12x1, A-coded to EN 61076-2-101 | ||
Reverse polarity protection | For all electrical connections | ||
Operational voltage range DC | 15 V ... 30 V | ||
IO-Link®, minimum cycle time | 1,2 ms | ||
IO-Link, Process data content IN | Flow rate measured value 16-bit MDC Flow rate monitoring 2-bit SSC Temperature measured value 16 bit MDC Temperature monitoring 2-bit SSC Volume / mass pulse 1 bit SSC | ||
IO-Link®, process data length output | 0 bit | ||
IO-Link, SIO-Mode support | Yes | ||
IO-Link®, device profile | Function extended identification Function measurement data, standard resolution Function multiple switching signal Firmware update Function locator Function Teach single value Function Teach two values Identification and diagnostics Smart sensor - SSP 4.1.2 | ||
Protocol | IO-Link® | ||
Short circuit current rating | yes | ||
Max. load resistance current output | 500 Ohm | ||
Output characteristic curve starting value | 4 mA | ||
Temperature characteristic curve end value | 100 °C | ||
Flow characteristic curve end value | 10 l/min ... 1.000 l/min | ||
Analogue output | 0 - 10 V 4 - 20 mA 1 - 5 V | ||
Switching element function | N/C or N/O contact, switchable | ||
Switching output | 2 x PNP or 2 x NPN, switchable | ||
Temperature coefficient span in ± %FS/K | Typ. 0.1%FS/K | ||
Repetition accuracy offset in ± %FS | 0,2 %FS | ||
Nominal temperature | 23 °C | ||
Media temperature | 0 °C ... 50 °C | ||
Operating pressure | 0 MPa ... 1 MPa | ||
Temperature measurement start value | 0 °C | ||
Start value for flow rate measuring range | 0,1 l/min ... 10 l/min | ||
Measuring principle | Thermal | ||
Measured variable | Mass flow rate Temperature Volume Volumetric flow rate | ||
Certificate issuing authority | UL E322346 | ||
Explosion ignition protection type for dust | Ex tc IIIB T80°C X Dc IP54 | ||
Explosion ignition protection type for gas | Ex nA IIC T5 X Gc | ||
Explosion protection | Zone 2 (ATEX) Zone 22 (ATEX) | ||
CE mark (see declaration of conformity) | To EU EMC Directive To EU Explosion Protection Directive (ATEX) In accordance with EU RoHS Directive | ||
Symbol | 00992242 00992243 00995566 |
Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
Pressure drop | < 100 mbar | ||
Protection against tampering | IO-Link PIN code | ||
Displayable units | g g/min l l/h l/min m3 m3/h scf scfm | ||
Material housing | PA-reinforced | ||
Pneumatic connection | For tubing O.D. 6 mm For tubing O.D. 8 mm For tubing outside diameter of 10 mm For tubing O.D. 12 mm For tubing outside Ø 1/4" For tubing outside Ø 5/16" For tubing outside Ø 3/8" | ||
Type of mounting | With through-hole With H-rail Via wall/surface bracket | ||
Electrical connection 1, number of connections/cores | 5 | ||
Electrical connection 1, connection type | Plugs | ||
No-load supply current | 90 mA ... 120 mA | ||
IO-Link, Data storage required | 500 Byte | ||
IO-Link, Service data IN | Volume / mass measured value 32 bit MDC | ||
IO-Link®, process data length input | 64 bit | ||
IO-Link®, port type | Class A | ||
IO-Link®, transmission rate | COM3 | ||
IO-Link®, revision ID | V1.1 | ||
Overload protection | Available | ||
Min. load resistance voltage output | 10 kOhm | ||
Output characteristic curve end value | 20 mA | ||
Output characteristic curve start value | 0 V | ||
Temperature characteristic curve start value | 0 °C | ||
Flow characteristic curve start value | 0 l/min | ||
Max. output current | 100 mA | ||
Switching function | Window comparator Threshold value comparator | ||
Pressure influence span in ± %FS/bar | 0,5 %FS/b. | ||
Repetition accuracy span in ± %FS | 0,8 %FS | ||
Accuracy of flow rate | ± (3% o.m.v. + 0.3% FS) | ||
Ambient temperature | 0 °C ... 50 °C | ||
Operating medium | Compressed air to ISO 8573-1:2010 [6:4:4] Compressed air to ISO 8573-1:2010 [7:4:4] Nitrogen | ||
Temperature measurement end value | 50 °C | ||
End value for flow rate measuring range | 3 l/min ... 1.000 l/min | ||
Measurement method | Heat Loss | ||
Flow direction | Unidirectional P1 -> P2 | ||
Note on materials | RoHS-compliant | ||
Explosion ambient temperature | 0°C <= Ta <= +50°C | ||
ATEX category dust | II 3D | ||
ATEX category gas | II 3G | ||
CE marking (see declaration of conformity) | To UK instructions for EMC To UK RoHS instructions | ||
Approval | RCM trademark c UL us - Recognized (OL) |