Conforms to standard | EN 61984 | ||
Electrical connection 1, function | Field device side | ||
Electrical connection 1, connection type | Socket | ||
Electrical connection 1, connector system | M12x1, A-coded to EN 61076-2-101 | ||
Electrical connection 1, used connections/cores | 8 | ||
Electrical connection 2, function | Controller side | ||
Electrical connection 2, connection type | Plugs | ||
Electrical connection 2, connector system | Sub-D | ||
Electrical connection 2, used connections/cores | 8 | ||
Operational voltage range DC | 0 V ... 30 V | ||
Operational voltage range AC | 0 V ... 30 V | ||
Current rating at 40°C | 3 A | ||
Immunity to surge | 0,5 kV | ||
Cable characteristic | Suitable for energy chains | ||
Bending radius, moving cable | ≥ 75 mm | ||
Cable structure | 1 x 4 x 0.14 mm² + 4 x 0.34 mm² Shielded | ||
Degree of protection | IP65 | ||
Ambient temperature | -40 °C ... 80 °C | ||
CE mark (see declaration of conformity) | In accordance with EU RoHS Directive | ||
LABS (PWIS) conformity | VDMA24364-B2-L | ||
Pollution degree | 3 |
Cable designation | Without inscription label holder | ||
Electrical connection 1, design | Round | ||
Electrical connection 1, cable outlet | Angled | ||
Electrical connection 1, number of connections/cores | 8 | ||
Electrical connection 1, connection pattern | 992.265 | ||
Electrical connection 2, design | Angular | ||
Electrical connection 2, cable outlet | Straight | ||
Electrical connection 2, number of connections/cores | 15 | ||
Electrical connection 2, connection pattern | 995.641 | ||
Nominal operating voltage DC | 24 V | ||
Nominal operating voltage AC | 24 V | ||
Note on permissible current load at 40°C | 2 A for conductor cross section 0.14 mm² | ||
Cable length | 10 m | ||
Bending radius, fixed cable | ≥ 20 mm | ||
Cable diameter | 6 mm | ||
Nominal cross section conductor | 0,34 mm² | ||
Note on degree of protection | IP30 for Sub-D plug connector In assembled state | ||
Ambient temperature with moving cable | -10 °C ... 80 °C | ||
CE marking (see declaration of conformity) | To UK RoHS instructions | ||
Note on materials | RoHS-compliant | ||
Material cable sheath | TPE-U(PUR) |