Design | Round | ||
Electrical output | Non-contacting, 2-wire | ||
Corrosion resistance class CRC | 1 - Low corrosion stress | ||
Ambient temperature with moving cable | -5 °C ... 50 °C | ||
Material housing | Brass PA Nickel-plated | ||
Mounting type | Flush | ||
Type of mounting | Via lock nut | ||
Material insulating sheath | PVC | ||
Cable length | 2,5 m | ||
Reverse polarity protection | For all electrical connections | ||
Mains frequency | 50 Hz | ||
Operational voltage range AC | 20 V ... 265 V | ||
Min. load current | 5 mA | ||
Max. output current | 300 mA | ||
Max. switching frequency DC | 200 Hz | ||
Switching element function | N/O contact | ||
Repetition accuracy | 0,3 mm | ||
Reduction factors | Aluminium = 0.4 Stainless steel St 18/8 = 0.7 Copper = 0.3 Brass = 0.4 Steel St 37 = 1.0 | ||
Rated operating distance | 10 mm | ||
CE mark (see declaration of conformity) | To EU EMC Directive To EU Low Voltage Directive | ||
Symbol | 991.712 |
Selection of sensor design | Standard | ||
Additional information for sensor selection | For DC and AC voltage | ||
Degree of protection | IP67 | ||
Switching status indication | Yellow LED | ||
Product weight | 190 g | ||
Tightening torque | 30 Nm | ||
Size | M30 | ||
Material cable sheath | TPE-U(PUR) | ||
Electrical connection | 2-wire Cable | ||
No-load supply current | ≤ 1,5 mA | ||
Operational voltage range DC | 20 V ... 320 V | ||
Short circuit current rating | no | ||
Voltage drop | ≤ 8 V | ||
Max. switching frequency AC | 25 Hz | ||
Hysteresis | 0,05 mm ... 2,2 mm | ||
Switching output | Non-contacting, 2-wire | ||
Ambient temperature | -25 °C ... 85 °C | ||
Assured operating distance | 8,1 mm | ||
Measuring principle | Inductive | ||
Approval | RCM trademark c UL us listed (OL) | ||
Conforms to standard | EN 60947-5-2 |