| Producto | dt8p1 : please refer to product catalog/contact csr for more details | ||
| application in domestic and commercial area permitted | no | ||
| 10.2.7 inscriptions | meets the product standard's requirements. | ||
| supply frequency | 50/60 hz | ||
| frame size | fr6 | ||
| assigned motor current im at 400 v, 50 hz, 110% overload | 55 a | ||
| 10.10 temperature rise | the panel builder is responsible for the temperature rise calculation. eaton will provide heat dissipation data for the devices. | ||
| 10.7 internal electrical circuits and connections | is the panel builder's responsibility. | ||
| rated frequency - max | 66 hz | ||
| Grado de protección | ip21 nema other |
||
| rated operational current (ie) at 150% overload | 46 a | ||
| 10.2.3.2 verification of resistance of insulating materials to normal heat | meets the product standard's requirements. | ||
| rated frequency - min | 45 hz | ||
| suitable for | branch circuits, (ul/csa) | ||
| rated control voltage (uc) | 24 v dc (external, max. 250 ma) | ||
| equipment heat dissipation, current-dependent pvid | 550 w | ||
| radio interference class | c2, c3: depending on the motor cable length, the connected load, and ambient conditions. external radio interference suppression filters (optional) may be necessary. | ||
| product category | variable frequency drives | ||
| heat dissipation per pole, current-dependent pvid | 0 w | ||
| 10.3 degree of protection of assemblies | does not apply, since the entire switchgear needs to be evaluated. | ||
| 10.2.6 mechanical impact | does not apply, since the entire switchgear needs to be evaluated. | ||
| Posición de montaje | vertical | ||
| 10.6 incorporation of switching devices and components | does not apply, since the entire switchgear needs to be evaluated. | ||
| number of inputs (digital) | 6 (parameterizable, max. 30 v dc) | ||
| voltage rating - max | 480 vac | ||
| heat dissipation details | operation (with 150 % overload) | ||
| connection to smartwire-dt | no | ||
| Frecuencia de conmutación | 10 khz, 1 - 16 khz adjustable, fpwm, power section, main circuit | ||
| output frequency - max | 320 hz | ||
| communication interface | canopen®, optional lonworks, optional modbus-tcp, optional profibus-dp devicenet, optional bacnet/ip, optional bacnet ms/tp, optional ethercat, optional ethernet ip, optional modbus-rtu, optional profinet, optional |
||
| number of relay outputs | 2 (parameterizable, n/o, 8 a (24 v dc) / 8 a (250 v ac) / 0,4 a (125 v dc)) | ||
| protection | finger and back-of-hand proof, protection against direct contact (bgv a3, vbg4) | ||
| 10.8 connections for external conductors | is the panel builder's responsibility. | ||
| rated operational power at 380/400 v, 50 hz | 22 kw | ||
| fitted with: | oled display dc link choke internal dc link radio interference suppression filter brake chopper igbt inverter |
||
| ambient storage temperature - min | -40 °c | ||
| 10.2.5 lifting | does not apply, since the entire switchgear needs to be evaluated. | ||
| 10.4 clearances and creepage distances | meets the product standard's requirements. | ||
| assigned motor current im at 440/480 v, 60 hz, 110% overload | 52 a | ||
| 10.11 short-circuit rating | is the panel builder's responsibility. the specifications for the switchgear must be observed. | ||
| mains voltage - max | 500 v | ||
| certifications | ce certified by ul for use in canada iec/en 61800-3 rohs, iso 9001 ul file no.: e134360 cul ul category control no.: nmms, nmms2, nmms7. nmms8 safety: en 61800-5-1: 2003 specification for general requirements: iec/en 61800-2 dnv iec/en61800-3 iec/en61800-5 ul report applies to both us and canada csa class no.: 3211-06 csa-c22.2 no. 14 rcm ul ul 508c |
||
| product width | 195 mm | ||
| product length/depth | 558 mm |
| industrial valves | dt8p1-10-5-11-in13 | ||
| altitude | max. 1000 m max. 3000 m above 1000 m with 1 % performance reduction per 100 m |
||
| 10.2.4 resistance to ultra-violet (uv) radiation | meets the product standard's requirements. | ||
| 10.2.2 corrosion resistance | meets the product standard's requirements. | ||
| converter type | other | ||
| assigned motor current im at 400 v, 50 hz, 150% overload | 41 a | ||
| ambient operating temperature at 150% overload - min | -10 °c | ||
| ambient storage temperature - max | 70 °c | ||
| rated operational current (ie) at 110% overload | 61 a | ||
| 10.9.2 power-frequency electric strength | is the panel builder's responsibility. | ||
| 10.2.3.3 resist. of insul. mat. to abnormal heat/fire by internal elect. effects | meets the product standard's requirements. | ||
| number of outputs (digital) | 1 (parameterizable, 48 v dc/50 ma) | ||
| operating mode | u/f control optional: vector control with feedback (clv) sensorless vector control (slv) |
||
| number of outputs (analog) | 1 | ||
| heat dissipation capacity pdiss | 0 w | ||
| assigned motor power at 460/480 v, 60 hz, 110% overload | 40 hp | ||
| assigned motor power at 460/480 v, 60 hz | 30 hp | ||
| resolution | 0.01 hz (frequency resolution, setpoint value) | ||
| electromagnetic compatibility | 1st and 2nd environments (according to en 61800-3) | ||
| 10.9.4 testing of enclosures made of insulating material | is the panel builder's responsibility. | ||
| 10.13 mechanical function | the device meets the requirements, provided the information in the instruction leaflet (il) is observed. | ||
| 10.5 protection against electric shock | does not apply, since the entire switchgear needs to be evaluated. | ||
| rated control supply voltage | 10 v dc (us, max. 10 ma) | ||
| ambient operating temperature - min | -10 °c | ||
| 10.9.3 impulse withstand voltage | is the panel builder's responsibility. | ||
| static heat dissipation, non-current-dependent pvs | 0 w | ||
| rated operational power at 380/400 v, 50 hz, 110% overload | 30 kw | ||
| output voltage (u2) | 400 v ac, 3-phase 480 v ac, 3-phase 500 v ac, 3-phase |
||
| climatic proofing | < 95 % relative humidity, no condensation, no corrosion, no dripping water | ||
| application in industrial area permitted | no | ||
| ambient operating temperature - max | 50 °c | ||
| ambient operating temperature at 150% overload - max | 50 °c | ||
| system configuration type | ac supply systems with earthed center point | ||
| output frequency - min | 0 hz | ||
| mains voltage - min | 380 v | ||
| 10.2.3.1 verification of thermal stability of enclosures | meets the product standard's requirements. | ||
| 10.12 electromagnetic compatibility | is the panel builder's responsibility. the specifications for the switchgear must be observed. | ||
| rated operational voltage | 480 v ac, 3-phase 500 v ac, 3-phase 400 v ac, 3-phase |
||
| number of inputs (analog) | 2 (parameterizable, 0 - 10 v dc, 0/4 - 20 ma) | ||
| rated operational current for specified heat dissipation (in) | 46 a | ||
| assigned motor current im at 440 - 480 v, 60 hz, 150% overload | 40 a | ||
| Peso del producto | 18.5 kg | ||
| product height | 237 mm | ||
| ean | 4015081232772 |
| Stock | 1 uds. |
|---|---|
| Referencia | 125667 |
| Fabricante | EATON |
| Unidades | Precio / Unidad |
|---|---|
| 1+ | 325,80 € |
Las cookies son pequeños archivos de texto que pueden mejorar la experiencia del usuario en los sitios web
La ley estipula que podemos almacenar las cookies estrictamente necesarias en su dispositivo para el correcto funcionamiento de este sitio. Para otros tipos de cookies, requerimos su permiso. Esto significa que las cookies necesarias se procesan según el art. 6 (1) (f), mientras que todas las demás cookies, como las de las categorías de preferencias y marketing, se procesan según el art. 6 (1) (a) RGPD.
cookies.cookies_about_type
Tiene la opción de cambiar o retirar su consentimiento en cualquier momento a través de la Declaración de cookies en nuestra sitio web.
Encuentre más información sobre nuestra identidad, cómo contactarnos y nuestras prácticas de procesamiento de datos personales en nuestra Política de Privacidad.