EATON 010303

diler-40-g(220vdc)

$224,69 $449,38 -50%
9 uds. con envío de 1 a 3 días a United States

Especificaciones

Mounting Position as required (except vertical with terminals a1/a2 at the bottom)
Ancho 45 mm
Peso 206g
power consumption (sealing) at dc 2.3 w
static heat dissipation, non-current-dependent pvs 2.3 w
code number 40e
ambient operating temperature - max 50 °c
screw size m3.5, terminal screw
rated control supply voltage (us) at ac, 50 hz - max 0 v
rated control supply voltage (us) at dc - min 220 v
ambient operating temperature (enclosed) - max 40 °c
10.2.5 lifting does not apply, since the entire switchgear needs to be evaluated.
10.12 electromagnetic compatibility is the panel builder's responsibility. the specifications for the switchgear must be observed.
rated control supply voltage (us) at ac, 50 hz - min 0 v
10.11 short-circuit rating is the panel builder's responsibility. the specifications for the switchgear must be observed.
rated operational current for specified heat dissipation (in) 6 a
certifications ul file no.: e29184
csa
csa file no.: 012528
vde 0660
ul
en 60947-5-1
ul category control no.: nkcr
iec/en 60947
iec/en 60947-4-1
csa class no.: 3211-03
csa-c22.2 no. 14-05
ce
ul 508
product width 45 mm
product length/depth 54 mm
rated insulation voltage (ui) 690 v
Shock resistance 8 g, n/c auxiliary contact, basic unit with auxiliary contact module, mechanical, according to iec/en 60068-2-27, half-sinusoidal shock 10 ms
10 g, n/o auxiliary contact, basic unit with auxiliary contact module, mechanical, according to iec/en 60068-2-27, half-sinusoidal shock 10 ms
short-circuit protection rating 10 a fast, 500v, maximum fuse, short-circuit rating without welding, contacts
rated control supply voltage (us) at ac, 60 hz - max 0 v
10.2.4 resistance to ultra-violet (uv) radiation meets the product standard's requirements.
duty factor 100 %
Tightening torque 1.2 nm, screw terminals
10.10 temperature rise the panel builder is responsible for the temperature rise calculation. eaton will provide heat dissipation data for the devices.
power consumption (pick-up) at dc 2.3 w
10.7 internal electrical circuits and connections is the panel builder's responsibility.
Pollution degree 3
Overvoltage category iii
control circuit reliability < 2 λ, < 1 failure at 100,000,000 operations (at uₑ = 24 v dc, umin = 17 v, imin = 5.4 ma)
terminal capacity (solid/stranded awg) 1 x (18 - 14)
2 x (18 - 14)
18 - 14
10.2.3.3 resist. of insul. mat. to abnormal heat/fire by internal elect. effects meets the product standard's requirements.
10.2.3.2 verification of resistance of insulating materials to normal heat meets the product standard's requirements.
short-circuit protection rating without welding 6 a gg/gl, 500 v, max. fuse, contacts
pick-up voltage 0.85 - 1.3 v dc x uc
0.7 - 1.3 v dc x uc (at 24 v: without auxiliary contact module and at ambient air temperature + 40 °c)
heat dissipation capacity pdiss 0 w
switching time (dc operated, make contacts, closing delay) - max 35 ms
switching capacity (auxiliary contacts, general use) 10 a, 600 v ac, (ul/csa)
0.5 a, 250 v dc, (ul/csa)
switching time (dc operated, make contacts, opening delay) - max 25 ms
rated operational current (ie) at ac-15, 380 v, 400 v, 415 v 3 a
heat dissipation per pole, current-dependent pvid .4 w
10.9.4 testing of enclosures made of insulating material is the panel builder's responsibility.
10.13 mechanical function the device meets the requirements, provided the information in the instruction leaflet (il) is observed.
Mounting position as required (except vertical with terminals a1/a2 at the bottom)
10.5 protection against electric shock does not apply, since the entire switchgear needs to be evaluated.
ambient operating temperature - min -25 °c
rated control supply voltage (us) at dc - max 220 v
rated operational current (ie) at ac-15, 500 v 1.5 a
Features positive operating contacts to en 60947-5-1 appendix l, including auxiliary contact module
climatic proofing damp heat, constant, to iec 60068-2-78
damp heat, cyclic, to iec 60068-2-30
protection finger and back-of-hand proof, protection against direct contact when actuated from front (en 50274)
10.8 connections for external conductors is the panel builder's responsibility.
fitted with: interlocked opposing contacts
10.2.3.1 verification of thermal stability of enclosures meets the product standard's requirements.
stripping length (main cable) 8 mm
mounting method din-rail/screw
10.4 clearances and creepage distances meets the product standard's requirements.
ambient operating temperature (enclosed) - min 25 °c
terminal capacity (flexible with ferrule) 1 x (0.75 - 1.5) mm²
2 x (0.75 - 1.5) mm²
switching time (dc operated, make contacts, opening delay) - min 15 ms
Product weight .206 kg
product height 58 mm
ean 4015080103035
switching capacity (auxiliary contacts, pilot duty) a600, ac operated (ul/csa)
p300, dc operated (ul/csa)
number of auxiliary contacts (normally open contacts) 4
number of contacts (normally open contacts) 4
10.2.7 inscriptions meets the product standard's requirements.
10.2.2 corrosion resistance meets the product standard's requirements.
screwdriver size 2, terminal screw, pozidriv screwdriver
0.8 x 5.5/1 x 6 mm, terminal screw, standard screwdriver
conventional thermal current ith at 50°c (3-pole, open) 10 a
rated impulse withstand voltage (uimp) 6000 v ac
switching time (dc operated, n/o, with auxiliary contact module, closing delay) 70 ms
rated control supply voltage (us) at ac, 60 hz - min 0 v
rated operational voltage (ue) at ac - max 600 v
Degree of protection ip20
10.9.2 power-frequency electric strength is the panel builder's responsibility.
lifespan, mechanical 20,000,000 operations (dc operated)
switching time (dc operated, make contacts, closing delay) - min 26 ms
terminal capacity (solid) 1 x (0.75 - 2.5) mm²
2 x (0.75 - 2.5) mm²
connection type (auxiliary circuit) screw connection
rated operational current (ie) 0.5 a at 220 v, dc l/r ≤ 15 ms (with 3 contacts in series)
2.5 a at 24 v, dc l/r ≤ 15 ms (with 1 contact in series)
2.5 a at 60 v, dc l/r ≤ 15 ms (with 2 contacts in series)
1.5 a at 110 v, dc l/r ≤ 15 ms (with 3 contacts in series)
equipment heat dissipation, current-dependent pvid 0 w
product category diler mini-contactors
voltage type dc
operating frequency 9000 operations/h
Application contactor relays
10.3 degree of protection of assemblies does not apply, since the entire switchgear needs to be evaluated.
10.2.6 mechanical impact does not apply, since the entire switchgear needs to be evaluated.
rated operational current (ie) at ac-15, 220 v, 230 v, 240 v 6 a
safe isolation 300 v ac, between coil and auxiliary contacts, according to en 61140
300 v ac, between auxiliary contacts, according to en 61140
10.6 incorporation of switching devices and components does not apply, since the entire switchgear needs to be evaluated.
10.9.3 impulse withstand voltage is the panel builder's responsibility.
voltage tolerance smoothed dc, three-phase bridge rectifiers or smoothed double-wave rectification
$224,69
Stock 9 uds.
Referencia 010303
Fabricante EATON
Unidades Precio / Unidad
1 - 4 $224,69
5+ $220,20
  • Registro abierto
    Crea una cuenta en el momento
  • Soporte 24/7
    Pregúntanos a cualquier hora
  • 100% Seguro
    Solo pagos seguros: transferencia bancaria, tarjeta de cédito y PayPal
  • Descuentos por volumen
    Optimice sus suministros