| ean | 4015081232819 | ||
| product height | 2020 mm | ||
| Peso del producto | 275 kg | ||
| assigned motor current im at 440 - 480 v, 60 hz, 150% overload | 302 a | ||
| rated operational current for specified heat dissipation (in) | 300 a | ||
| rated operational voltage | 500 v ac, 3-phase 480 v ac, 3-phase 400 v ac, 3-phase |
||
| output at quadratic load at rated output voltage - max | 200 kw | ||
| 10.2.3.1 verification of thermal stability of enclosures | meets the product standard's requirements. | ||
| mains voltage - min | 380 v | ||
| output frequency - min | 0 hz | ||
| ambient operating temperature - max | 50 °c | ||
| communication interface | bacnet/ip, optional canopen®, optional profibus-dp lonworks, optional devicenet, optional modbus-tcp, optional bacnet ms/tp, optional ethercat, optional ethernet ip, optional modbus-rtu, optional profinet, optional |
||
| output voltage (u2) | 500 v ac, 3-phase 400 v ac, 3-phase 480 v ac, 3-phase |
||
| heat dissipation details | operation (with 150 % overload) | ||
| 10.6 incorporation of switching devices and components | does not apply, since the entire switchgear needs to be evaluated. | ||
| 10.2.6 mechanical impact | does not apply, since the entire switchgear needs to be evaluated. | ||
| assigned motor power at 460/480 v, 60 hz, 3-phase, 110 % overload | 300 hp | ||
| radio interference class | c2, c3: depending on the motor cable length, the connected load, and ambient conditions. external radio interference suppression filters (optional) may be necessary. | ||
| rated control voltage (uc) | 24 v dc (external, max. 250 ma) | ||
| rated operational current (ie) at 150% overload | 300 a | ||
| 10.9.2 power-frequency electric strength | is the panel builder's responsibility. | ||
| ambient storage temperature - max | 70 °c | ||
| output at linear load at rated output voltage - max | 160 kw | ||
| converter type | u converter | ||
| 10.2.2 corrosion resistance | meets the product standard's requirements. | ||
| 10.2.4 resistance to ultra-violet (uv) radiation | meets the product standard's requirements. | ||
| application in domestic and commercial area permitted | yes | ||
| number of phases (output) | 3 | ||
| 10.12 electromagnetic compatibility | is the panel builder's responsibility. the specifications for the switchgear must be observed. | ||
| number of hw-interfaces (rs-485) | 1 | ||
| 10.8 connections for external conductors | is the panel builder's responsibility. | ||
| number of relay outputs | 2 (parameterizable, n/o, 8 a (24 v dc) / 8 a (250 v ac) / 0,4 a (125 v dc)) | ||
| climatic proofing | < 95 % relative humidity, no condensation, no corrosion, no dripping water | ||
| static heat dissipation, non-current-dependent pvs | 0 w | ||
| voltage rating - max | 480 vac | ||
| rated control supply voltage | 10 v dc (us, max. 10 ma) | ||
| Posición de montaje | vertical | ||
| 10.9.4 testing of enclosures made of insulating material | is the panel builder's responsibility. | ||
| heat dissipation per pole, current-dependent pvid | 0 w | ||
| relative symmetric net voltage tolerance | 10 % | ||
| number of outputs (analog) | 1 | ||
| rated operational power at 380/400 v, 50 hz, 3-phase | 160 kw | ||
| rated frequency - min | 45 hz | ||
| 10.2.3.2 verification of resistance of insulating materials to normal heat | meets the product standard's requirements. | ||
| number of hw-interfaces (other) | 1 | ||
| rated frequency - max | 66 hz | ||
| ambient operating temperature at 150% overload - min | -10 °c | ||
| 10.10 temperature rise | the panel builder is responsible for the temperature rise calculation. eaton will provide heat dissipation data for the devices. | ||
| number of phases (input) | 3 | ||
| industrial valves | dt8p1-06-65-11-in13 |
| product length/depth | 602 mm | ||
| product width | 595 mm | ||
| certifications | cul iec/en61800-5 ul ul category control no.: nmms, nmms2, nmms7. nmms8 safety: en 61800-5-1: 2003 iec/en 61800-3 ul file no.: e134360 ce certified by ul for use in canada csa class no.: 3211-06 rcm iec/en61800-3 specification for general requirements: iec/en 61800-2 csa-c22.2 no. 14 dnv rohs, iso 9001 ul report applies to both us and canada ul 508c |
||
| mains voltage - max | 500 v | ||
| 10.11 short-circuit rating | is the panel builder's responsibility. the specifications for the switchgear must be observed. | ||
| 10.4 clearances and creepage distances | meets the product standard's requirements. | ||
| output voltage - max | 500 v | ||
| ambient storage temperature - min | -40 °c | ||
| fitted with: | control unit dc link choke pc connection radio interference suppression filter internal dc link igbt inverter oled display |
||
| ambient operating temperature at 150% overload - max | 50 °c | ||
| rated operational power at 380/400 v, 50 hz, 3-phase, 110% overload | 200 kw | ||
| output frequency - max | 320 hz | ||
| Frecuencia de conmutación | 3.6 khz, 1 - 6 khz adjustable, fpwm, power section, main circuit | ||
| ambient operating temperature - min | -10 °c | ||
| nominal output current i2n | 385 a | ||
| 10.3 degree of protection of assemblies | does not apply, since the entire switchgear needs to be evaluated. | ||
| product category | variable frequency drives | ||
| heat dissipation capacity pdiss | 0 w | ||
| assigned motor power at 460/480 v, 60 hz, 3-phase | 250 hp | ||
| Protocolo | other bus systems tcp/ip devicenet data-highway profibus can lon |
||
| Grado de protección | nema 1 ip21 |
||
| functions | 4-quadrant operation possible | ||
| assigned motor current im at 400 v, 50 hz, 110% overload | 349 a | ||
| frame size | fr10 | ||
| supply frequency | 50/60 hz | ||
| 10.2.7 inscriptions | meets the product standard's requirements. | ||
| number of inputs (analog) | 2 | ||
| assigned motor current im at 440/480 v, 60 hz, 110% overload | 361 a | ||
| 10.2.5 lifting | does not apply, since the entire switchgear needs to be evaluated. | ||
| system configuration type | ac supply systems with earthed center point | ||
| protection | finger and back-of-hand proof, protection against direct contact (bgv a3, vbg4) | ||
| application in industrial area permitted | yes | ||
| connection to smartwire-dt | no | ||
| 10.9.3 impulse withstand voltage | is the panel builder's responsibility. | ||
| number of inputs (digital) | 6 | ||
| 10.5 protection against electric shock | does not apply, since the entire switchgear needs to be evaluated. | ||
| 10.13 mechanical function | the device meets the requirements, provided the information in the instruction leaflet (il) is observed. | ||
| electromagnetic compatibility | 1st and 2nd environments (according to en 61800-3) | ||
| resolution | 0.01 hz (frequency resolution, setpoint value) | ||
| equipment heat dissipation, current-dependent pvid | 4000 w | ||
| suitable for | branch circuits, (ul/csa) | ||
| operating mode | optional: vector control with feedback (clv) u/f control sensorless vector control (slv) |
||
| number of outputs (digital) | 1 | ||
| 10.2.3.3 resist. of insul. mat. to abnormal heat/fire by internal elect. effects | meets the product standard's requirements. | ||
| rated operational current (ie) at 110% overload | 385 a | ||
| 10.7 internal electrical circuits and connections | is the panel builder's responsibility. | ||
| relative symmetric net frequency tolerance | 10 % | ||
| assigned motor current im at 400 v, 50 hz, 150% overload | 279 a | ||
| altitude | max. 1000 m max. 3000 m above 1000 m with 1 % performance reduction per 100 m |
||
| Producto | dt8p1 : please refer to product catalog/contact csr for more details |
| Stock | 1 uds. |
|---|---|
| Referencia | 125671 |
| Fabricante | EATON |
| Unidades | Precio / Unidad |
|---|---|
| 1+ | 154,66 € |
Las cookies son pequeños archivos de texto que pueden mejorar la experiencia del usuario en los sitios web
La ley estipula que podemos almacenar las cookies estrictamente necesarias en su dispositivo para el correcto funcionamiento de este sitio. Para otros tipos de cookies, requerimos su permiso. Esto significa que las cookies necesarias se procesan según el art. 6 (1) (f), mientras que todas las demás cookies, como las de las categorías de preferencias y marketing, se procesan según el art. 6 (1) (a) RGPD.
cookies.cookies_about_type
Tiene la opción de cambiar o retirar su consentimiento en cualquier momento a través de la Declaración de cookies en nuestra sitio web.
Encuentre más información sobre nuestra identidad, cómo contactarnos y nuestras prácticas de procesamiento de datos personales en nuestra Política de Privacidad.