temperature compensation | continuous ≤ 0.25 %/k, residual error for t > 40° |
||
heat dissipation capacity pdiss | 0 w | ||
rated operational current (ie) at dc-13, 60 v | .75 a | ||
product category | accessories overload relay zb up to 150 a |
||
rated operational current (ie) at ac-15, 380 v, 400 v, 415 v | .9 a | ||
number of contacts (normally closed contacts) | 1 | ||
10.2.6 mechanical impact | does not apply, since the entire switchgear needs to be evaluated. | ||
class | class 10 a | ||
safe isolation | 440 v ac, between main circuits, according to en 61140 440 v, between auxiliary contacts and main contacts, according to en 61140 240 v ac, between auxiliary contacts, according to en 61140 |
||
10.6 incorporation of switching devices and components | does not apply, since the entire switchgear needs to be evaluated. | ||
voltage rating - max | 600 vac | ||
electrical connection type of main circuit | screw connection | ||
Features | test/off button trip-free release phase-failure sensitivity (according to iec/en 60947, vde 0660 part 102) reset pushbutton manual/auto |
||
ambient operating temperature - max | 55 °c | ||
protection | finger and back-of-hand proof, protection against direct contact when actuated from front (en 50274) | ||
screw size | m10, terminal screw, main cables m3.5, terminal screw, control circuit cables 5 mm af, hexagon socket-head spanner, terminal screw, main cables |
||
short-circuit current rating (basic rating) | 200 a, max. cb, sccr (ul/csa) 5 ka, sccr (ul/csa) 225 a, max. fuse, sccr (ul/csa) |
||
10.2.3.1 verification of thermal stability of enclosures | meets the product standard's requirements. | ||
stripping length (main cable) | 24 mm | ||
mounting method | direct mounting direct attachment |
||
10.4 clearances and creepage distances | meets the product standard's requirements. | ||
stripping length (control circuit cable) | 8 mm | ||
terminal capacity (flexible with ferrule) | 2 x (4 - 70) mm², main cables 1 x (0.75 - 2.5) mm², control circuit cables 2 x (0.75 - 2.5) mm², control circuit cables 1 x (4 - 70) mm², main cables |
||
certifications | csa class no.: 3211-03 iec/en 60947-4-1 ul category control no.: nkcr vde 0660 ce csa file no.: 012528 csa-c22.2 no. 60947-4-1-14 ul 60947-4-1 csa iec/en 60947 ul ul file no.: e29184 |
||
product width | 118 mm | ||
product length/depth | 134 mm | ||
switching capacity (auxiliary contacts, pilot duty) | r300, dc operated (ul/csa) b600 at opposite polarity, ac operated (ul/csa) b300 at opposite polarity, ac operated (ul/csa) |
||
Shock resistance | 10 g, mechanical, sinusoidal, shock duration 10 ms | ||
rated operational current (ie) at dc-13, 110 v | .4 a | ||
short-circuit protection rating | max. 6 a gg/gl, fuse, without welding, auxiliary and control circuits 125 a gg/gl, fuse, type “2” coordination 160 a gg/gl, fuse, type “1” coordination |
||
10.2.7 inscriptions | meets the product standard's requirements. | ||
10.2.2 corrosion resistance | meets the product standard's requirements. | ||
screwdriver size | 2, terminal screw, control circuit cables, pozidriv screwdriver 1 x 6 mm, terminal screw, control circuit cables, standard screwdriver |
||
adjustable current range - max | 50 a | ||
10.10 temperature rise | the panel builder is responsible for the temperature rise calculation. eaton will provide heat dissipation data for the devices. | ||
10.7 internal electrical circuits and connections | is the panel builder's responsibility. | ||
Overvoltage category | iii | ||
10.9.2 power-frequency electric strength | is the panel builder's responsibility. | ||
overload release current setting - max | 50 a | ||
rated operational current (ie) at dc-13, 220 v, 230 v | .2 a | ||
10.2.3.2 verification of resistance of insulating materials to normal heat | meets the product standard's requirements. | ||
terminal capacity (solid) | 1 x (0.75 - 4) mm², control circuit cables 2 x (4 - 16) mm², main cables 1 x (4 - 16) mm², main cables 2 x (0.75 - 4) mm², control circuit cables |
suitable for | branch circuits, (ul/csa) | ||
equipment heat dissipation, current-dependent pvid | 21.6 w | ||
overload release current setting - min | 35 a | ||
heat dissipation per pole, current-dependent pvid | 7.2 w | ||
10.3 degree of protection of assemblies | does not apply, since the entire switchgear needs to be evaluated. | ||
10.9.4 testing of enclosures made of insulating material | is the panel builder's responsibility. | ||
10.13 mechanical function | the device meets the requirements, provided the information in the instruction leaflet (il) is observed. | ||
rated operational current (ie) at ac-15, 220 v, 230 v, 240 v | 1.5 a | ||
10.5 protection against electric shock | does not apply, since the entire switchgear needs to be evaluated. | ||
ambient operating temperature - min | -25 °c | ||
10.9.3 impulse withstand voltage | is the panel builder's responsibility. | ||
static heat dissipation, non-current-dependent pvs | 0 w | ||
climatic proofing | damp heat, constant, to iec 60068-2-78 damp heat, cyclic, to iec 60068-2-30 |
||
terminal capacity (stranded) | 1 x (16 - 70) mm², main cables 2 x (16 - 70) mm², main cables |
||
adjustable current range - min | 35 a | ||
10.8 connections for external conductors | is the panel builder's responsibility. | ||
reset function | automatic push-button |
||
ambient operating temperature (enclosed) - max | 40 °c | ||
10.2.5 lifting | does not apply, since the entire switchgear needs to be evaluated. | ||
10.12 electromagnetic compatibility | is the panel builder's responsibility. the specifications for the switchgear must be observed. | ||
ambient operating temperature (enclosed) - min | 25 °c | ||
10.11 short-circuit rating | is the panel builder's responsibility. the specifications for the switchgear must be observed. | ||
rated operational current for specified heat dissipation (in) | 50 a | ||
Product weight | 1.193 kg | ||
product height | 135 mm | ||
ean | 4015082784621 | ||
rated operational current (ie) at dc-13, 24 v | .9 a | ||
rated operational voltage (ue) - max | 1000 v | ||
number of auxiliary contacts (normally open contacts) | 1 | ||
number of contacts (normally open contacts) | 1 | ||
10.2.4 resistance to ultra-violet (uv) radiation | meets the product standard's requirements. | ||
rated operational current (ie) at ac-15, 120 v | 1.5 a | ||
frame size | zb150 | ||
Tightening torque | 1.2 nm, screw terminals, control circuit cables 10 nm, screw terminals, main cables |
||
rated impulse withstand voltage (uimp) | 8000 v ac 4000 v (auxiliary and control circuits) |
||
Pollution degree | 3 | ||
Degree of protection | ip00 | ||
terminal capacity (solid/stranded awg) | 3/0, main cables 2 x (18 - 14), control circuit cables |
||
conventional thermal current ith of auxiliary contacts (1-pole, open) | 6 a | ||
10.2.3.3 resist. of insul. mat. to abnormal heat/fire by internal elect. effects | meets the product standard's requirements. | ||
number of auxiliary contacts (normally closed contacts) | 1 |